TA100 is a transient absorption spectrometer designed to probe photoinduced electronic transitions and their evolution dynamics. It covers UV-Vis-NIR-MIR spectral ranges (femtosecond to microsecond timescales) and integrates a microscopic system for spatially resolved transient absorption measurements. The system supports wide-field excitation/detection or spot excitation with a high-speed CMOS camera for spatial defect analysis and carrier diffusion mapping. With optional 50kHz high-speed detectors (sensitivity 10-5 OD) and expandable TCSPC/ultrafast fluorescence modules, it enables comprehensive fluorescence kinetic analysis. This all-in-one solution includes complete pump-probe optics, microscopy, spectral/imaging acquisition, and dedicated data processing software. | |||||||||
Products Features
Multi-mode Multi-range Detection: Equipped with transmission, reflection, and back-excitation modes. Detection spectrum covers UV to NIR bands, suitable for diverse samples including tetracene dimers and CdSe quantum dots, delivering excellent performance across UV-NIR ranges.
High Resolution: Temporal resolution ≤1.5×femtosecond laser pulse width; Spatial resolution ≤1μm (microscopic dynamics imaging module). Enables precise capture of transient processes, supporting carrier migration studies in photocatalysis and perovskite solar cells.
Automation & Intelligence: Fully automated optical path switching/calibration ensures operational stability. Integrated software for data acquisition/analysis improves experimental efficiency.
High Expandability: Modular design allows flexible configuration upgrades.
Specifications
Laser type | Ti:Sapphire Lasers | Yb-based Lasers |
Spectral range | 280 - 380 nm | 350 - 500 nm |
320 - 650 nm | 480 - 950 nm | |
420 - 800 nm | 1100 - 1650 nm | |
850 - 1500 nm | -- | |
Mode | Transmission/reflection/backside excitation | |
Time window | 8 ns | |
Sensitivity | ≤10-5 OD | |
IRF | ≤ 1.5x Pulse Width | |
Automation System | Fully automated optical path switching and alignment | |
Sample holder | solution, film, and powder | |
External Field Control | low temp., high pressure, magnetic field, and other customer specific requirments | |
Software | Data acquisition, data analysis and fitting, and more |
Microscopic kinetics imaging module
Mode | Micro spectroscopy acquisition/wide-field TA imaging/carrier migration imaging |
Spatial resolution | ≤1 μm |
Wavelength range | 400-800 nm |
Carrier migration accuracy | 100 nm |
Nanosecond TA module
Spectral detection range | 380-950 nm; 1100-1600 nm |
Time window | ≤450 μs (Extendable to ms) |
time resolution | ≤ 1 ns |
Other expandable options
MIR Detection Range | 2-12 μm |
TCSPC module time resultion | Time Resolution ≤100 ps |
Ultrafast fluorescence module Time Resolution | ≤1.5X Pulsewidth |
Angular Resolution Module | Expandable for angular resolution detection |